How we work
Call us, message us on WhatsApp, or request your quote online — we'll reply in under 10 minutes during business hours. Daikin, Mitsubishi Electric, LG, Toshiba, Hitachi, Panasonic. For rooftop units: Carrier, York, Lennox. Selection based on power, budget, and availability. Electrical checks include nominal compressor consumption on startup and running, insulation check of wiring, condition of start capacitors (which degrade from the seventh or eighth year), and thermostat verification. Final disinfection with a certified air conditioning product eliminates bacteria, fungi, and odours accumulated in the coil. This prevents the characteristic damp smell when you turn on the air conditioning after winter.