If air conditioning cools poorly in Sant Gervasi - Galvany, do not assume it needs refrigerant. Record system type, model, error code and whether the symptom is low airflow, warm air, dripping or intermittent shutdown. Check only the mode, setpoint and accessible vents. Do not open electrical or refrigerant connections. The neighbourhood cannot establish the right capacity for a home.
Diagnosing the problem
Dirty filters can restrict airflow, but fans, sensors, drains or electrical components may also be involved. Do not break ice from a frozen unit. Record when dripping begins. Refrigerant top-up alone does not resolve a leak; the cause needs investigation under applicable rules. When comparing repair with replacement, ask for return-air and supply-air temperatures, airflow observations and the conditions under which the fault occurs. A system that cools one room but not another may have an air-distribution or return-air problem rather than insufficient cooling capacity. Where condensate drainage crosses a ceiling void, identify known inspection access and routing; opening finishes should be agreed as part of the scope. For vibration, distinguish fan noise from sound transmitted through brackets or pipework. Do not handle refrigerant or electrical connections to investigate these symptoms yourself. Before accepting a proposal, request a clear list of measurements, components to be checked and the post-work operating test. Cleaning a filter is not a substitute for diagnosing sensors, motors or drainage. If replacement is recommended, ask how room use, orientation and actual heat loads inform equipment sizing rather than relying only on floor area. Outdoor-unit positioning may require permission and safe access, neither of which can be assumed from an address. Keep error codes, photographs and test results so the options can be compared. The quotation should distinguish investigation from parts, installation, commissioning and any necessary reinstatement.
Safety and technical limits
For ducted systems, identify affected rooms and blocked returns. For multi-splits, distinguish one indoor unit from all units. Sizing requires floor area, orientation and heat-load information. Bigger equipment does not automatically improve comfort. Noise, vibration and distribution need on-site assessment.
Planning the work
Spain's thermal-installation rules and refrigerant regulations may apply. Do not handle valves. Check safe access, condensate drainage and community restrictions for outdoor units. Façade installation cannot be promised without permissions. Water near electrical wiring requires safety precautions.
Scope and quotation
Request a written quotation for diagnosis, tests, parts, cleaning, refrigerant work and required records. For replacement, specify locations, pipework, consumption and warranty. The Catalan Consumer Agency explains quotation and invoice rights. No price or appointment is verified.
Check stable operation, condensate discharge and absence of visible leaks. Retain test results, replaced parts and maintenance guidance. If the fault returns, record operating time, approximate outdoor temperature and error code. Handover tests must match the agreed scope.