How we work
Leak detection and repair, parts replacement, or gas recharge based on diagnosis. We arrive with a complete set of instruments. Manometers for pressures, contact and infrared thermometers, electronic gas leak detector, multimeter, and clamp meter for electrical measurements. We also bring the specific diagnostic application for each brand to read error codes stored on the board. Diagnosis begins with a brief interview with the client about when the problem started, how it manifests, if anything unusual happened beforehand (storm, unit moved, impact). It's followed by a visual inspection for oil stains indicating leaks, visible mechanical damage, or accumulated dirt. Then, electrical measurements and refrigerant analysis with manometers. Once the cause is identified, a fixed repair quote is provided, compared against the cost of a new unit if the fault is major.